Physiology #13 | Electrocardiographic Interpretation: Vectorial Analysis and Mean Electrical Axis

The Electrocardiogram

Instructor: Dr. Süleyman Burak ÇELİK

During each beat the current of the ventricles can be drawn as an arrow, a vector, whose direction and length change from moment to moment. In the 3D animation at the start we watch this arrow turn inside a sectioned heart and trace the QRS loop. In this lesson we answer two questions: why the same heart draws a different wave in every lead, and how the mean electrical axis is found from two leads. In this lesson: - The arrow-and-ruler model: the vector, the lead axis and the projected vector; parallel gives full length, 60° half, perpendicular almost zero - Directions in degrees and the hexagonal reference system: lead I 0°, II +60°, III +120°, aVF +90°, aVL −30°, aVR +210°; normal mean QRS vector about +59° - The QRS vectorcardiogram from 0.01 to 0.06 s, and why the normal T wave is positive in all three leads - Example 1: a 2 mV vector at +55° gives about 1 mV upward in lead I; at +100° about −0.3 mV; 1/2 + 1/3 = 5/6 in lead II; aVR: 210° − 55° = 155°, so the record is inverted - Example 2, the mean electrical axis: net zero in lead I means ±90°; lead III: 120° − 90° = 30° (up), 360° − 210° = 150° (down), so the axis is +90°, within the normal range of 20° to 100° - Axis deviation from heart position, ventricular hypertrophy and bundle branch block: about −50° in left and 105° in right bundle branch block - Example 3: right hypertrophy at 170°, 170° − 59° = 111° right of normal; left hypertrophy at −15°; 170° − 120° = 50°, 120° + 15° = 135°; QRS 0.06–0.08, 0.09–0.12 and 0.14 s or longer - The current of injury (axis about 125°: 125° − 60° = 65°, 125° − 120° = 5°) and the J point as the true zero; three common misconceptions Chapters: 0:00 Exam question: what is the mean electrical axis? 0:25 Recap and today's question 0:59 The arrow-and-ruler model: vectors and projected vectors 2:09 Degrees, lead axes and the hexagonal reference system 2:56 The QRS vectorcardiogram and the T wave 3:52 Example 1: the shadow of a vector 4:35 A vector at +55°: about 1 mV upward in lead I 5:21 A vector at +100°: a downward record 6:06 Lead II: 1/2 + 1/3 = 5/6 6:49 Checks and the axis of aVR 7:39 Example 2: the mean electrical axis from two leads 8:23 Zero net value in lead I 9:03 Lead III chooses the direction: +90° 9:53 The normal range and the position of the heart 10:34 Where the wrong options come from 11:04 Two checks and the shortcut 11:56 Axis deviation: hypertrophy and bundle branch block 12:44 Example 3: right and left ventricular hypertrophy 13:28 Step one: 111 degrees to the right 14:06 Step two: reading the shadows in leads I and III 15:00 Step three: why the arrow turns toward the thick side 15:40 QRS duration: hypertrophy versus bundle branch block 16:27 The current of injury 17:28 The J point 18:17 Three common misconceptions 18:47 Summary 19:22 The rule to remember Reference textbook: J. E. Hall, Guyton and Hall Textbook of Medical Physiology, 13th ed., Elsevier, 2016, Chapter 12. Definitions and numerical values follow the book; the 3D scene, drawings and worked examples are original. Next lesson: cardiac arrhythmias. This video is for educational purposes only and is not medical advice.